Emergency switch-off: If a certain temperature is exceeded, or the waterflow is below or above a limit, the emergency switch will be activated. It is connected between ATX power switch and mainboard. First a soft switch-off will be tried (Windows shut down), after a while a hard switch-off. Limits and times are custom configurable.
Analog sensors:
You can connect up to 6 analog temperature sensors, thin foil
sensors (0.4mm) or
water temperature probes.
Microprocessor: A separate microprocessor is linearising the analog sensors. By standard analog sensors have strong deviations. But with linearising, analog sensors get so precise that their perfomance comes close to that of the digital sensors.
I2C-SMBus:
The sensor bus will be connected like the digital sensors over the
bus to the T-Balancer. Analog sensors can be used in addition to the
digital sensors. That sums up to 14 possible temperature sensors.
Flowmeter: You can connect up to 2 flowmeters and configure the puls rate to ensure a high compability to other flowmeters. |